You’ll get all the features and benefits of the lightweight waterless 5500 Meter with a few added benefits.
- PIG Screen (Probability of Ignition)
- FDFM Screen (Fine Dead Fuel Moisture)
Advantage over the Kestrel 3000 & Kestrel 3500FW models: You won’t need to calibrate this meter! Kestrel AU will stand by this and other 5000 series models to hold calibration within drift for 5 years. Kestrel AU will repair, recalibrate or replace any defective product within the warranty period. “Defective” includes measurements outside of our accuracy spec plus stated drift.
RH (Relative Humidity):
- Accuracy: +/- 2%RH
- Sensors: 10 to 90% 25°C non-condensing
- Calibration Drift: Typically less than +/- 0.25% per year!
To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight.
Models & SKUs:
- Kestrel 5500FW Fire Weather Pro with Compass: 0855FWORA
- Kestrel 5500FW Fire Weather Pro with Compass + LiNK + Vane Mount: 0855FWLVORA
- PIG Screen (Probability of Ignition)
- FDFM Screen (Fine Dead Fuel Moisture)
- Waterless! Natural Wet Bulb Temperature accurately calculated from on-board digital sensors with no tedious setup or maintenance.
- Large, hi-res, hi-contrast, graphic display is perfectly readable in the brightest sunlight and is backlit for use in low-light conditions.
- Globe Temperature
- Naturally Aspirated Wet Bulb Temperature
- Wind Speed (Current, Average, & Maximum)
- Altitude
- Pressure trend
- Barometric pressure
- Relative humidity in %
- Accuracy: +/- 2%RH
- Sensors: 10 to 90% 25°C non-condensing
- Calibration Drift: Typically less than +/- 0.25% per year!
- Heat stress index
- Dewpoint
- Wet bulb temperature
- Density altitude
- Wind chill
- Air, water, and snow temperature °F or °C
- Waterproof and floats
- Time and date
- Easy- to-read backlit display
- Data Logger (automatic and manual)
- Customizable data storage – 2900 data points
- Humidity sensor can be calibrated in the field with our Relative Humidity Calibration Kit.
- Customize screens to display user-selected measurements
- Graph and recall trends
- User-replaceable impeller
- Data charting
- Upload to a computer (with optional interface)
- Meets MIL-STD-810F 516.5 Procedure IV Transit Shock test – 20 drops from 5 ft. IP-67 sealed to exclude dust and water at 3 ft. submersion
- Five languages (English, French, Spanish, German, and Italian)
- US Patent Nos. 5,783,753 and 5,939,645 and 6,257,074
- Made in the USA
- 5 Year Warranty